Select Page

CRRC 2MW Air-to-Water Cooled Double Fed Induction Generator

CRRC 2MW air-water-cooled doubly fed Induction generator set, paired with a 2MW variable-frequency doubly fed wind turbine generator set, is suitable for inland and high-altitude wind farms. The generator set is installed in the nacelle, with the drive shaft connected to the gearbox via a coupling to receive mechanical power. The stator is grid-connected, and the rotor is grid-connected via a four-quadrant converter. Its speed can operate within ±36.7% of synchronous speed, converting mechanical energy into electrical energy.

As a key component of the wind turbine generator set, it mainly includes an air-water cooler, welded frame, core winding assembly, insulating end caps, three-phase wound rotor, slip ring brush holder assembly and slip ring chamber, stator and rotor junction boxes, sensors and auxiliary junction box devices, lightning protection devices, encoders, etc.

We provide full lifecycle support for the 2MW air-water-cooled doubly fed Induction generator set, including equipment supply, on-site installation and commissioning, maintenance training, spare parts supply, and ongoing technical troubleshooting services.

Advantages of CRRC 2MW Air-to-Water Cooled Double Fed Induction Generator

  • Lightweight design, low-temperature motor.

  • Dual-channel circulation ventilation structure provides excellent heat dissipation.

  • Specially designed rotor wiring with patented technology enhances rotor reliability.

  • Uses low-temperature resistant materials to meet the requirements of low-temperature operating conditions.

  • High-speed dynamic balancing process reduces motor vibration and noise.

  • Product is certified by classification societies.

Technical Specifications

Rated Power: 2150 kW
Rated Speed: 1755 rpm
Rated Frequency: 50 Hz
Shaft Center Height: 500 mm
Rated Stator Voltage: 690 V
Rated Rotor Voltage: 312 V
Rated Stator Current: 1540 A
Rated Rotor Current: 614 A
Stator / Rotor Winding Connection: △ / Y
Number of Poles: 4
Open-Circuit Rotor Voltage: 1835 V ± 20 V
Protection Class: IP54 / IP23
Cooling Method: Air-to-Water Cooled
Weight: 6500 kg

 

coming soon

coming soon

Product Name

Rated Power

Rated Speed

Rated Voltage

Rated Current

Rated Frequency

Rated Efficiency

Protection Class

Cooling Method

Weight

1.5MW Generator 1560 kW 1800 rpm 690 V / 420 V 1090 A / 390 A 50 Hz ≥97% IP54/IP23 Air-to-Air + Water Jacket 7200 kg
2.5MW Generator 2560 kW 1720 rpm 690 V 1877 A 50 Hz N/A IP54 IC666 8100 kg
3.3MW Generator 3400 kW 1720 rpm 690 V 2493 A 50 Hz N/A IP54 IC616 10000 kg
4.2MW Generator 4200~4300 kW 1720~1780 rpm 1140 V 637 A 50 Hz N/A N/A IC2X N/A
6.4MW Generator 6400 kW 1720 rpm 1140 V 962 A 50 Hz N/A N/A IC26 11500 kg
1.5MW AAC Generator 1560 kW 1800 rpm 690 V / 420 V 1090 A / 390 A 50 Hz ≥97% IP54/IP23 Air-to-Air Cooling 7200 kg
2MW AAC Generator 2150 kW 1200 rpm 690 V / 401 V 1506 A / 624 A 50 Hz ≥97% IP54/IP23 Air-to-Air Cooling 9500 kg
2.XMW AAC Generator 2280~2600 kW 1650~1820 rpm 690 V N/A 50 Hz ≥96.5% IP54/IP23 (Slip Ring Chamber) IC616 7500 kg
4.XMW AAC Generator 3600~4200 kW 1200 r/min 690 V N/A 50 Hz ≥97% IP54/IP23 Air-to-Air Cooling N/A
1.5MW Plateau AAC Generator 1567 kW 1735 rpm 690 V / 300 V 1138 A / 459 A 50 Hz ≥97% IP54/IP23 (Slip Ring Chamber) Air-to-Air Cooling 7600 kg
2MW Plateau AAC Generator 2150 kW 1800 rpm 690 V / 389 V 1506 A / 590 A 50 Hz ≥97% IP54/IP23 Air-to-Air Cooling 7800 kg
2.5MW Plateau AAC Generator 2600 kW 1200 rpm 690 V / 415 V 1822 A / 665 A 50 Hz ≥97% IP54/IP23 (Slip Ring Chamber) Air-to-Air Cooling 11300 kg
2.5MW Low Temp AAC Generator 2600 kW 1200 rpm 690 V / 415 V 1820 A / 670 A 50 Hz 97% IP54/IP23 IC666 11900 kg
2MW AWC Generator 2150 kW 1755 rpm 690 V / 312 V 1540 A / 614 A 50 Hz ≥97% IP54/IP23 Air-to-Water Cooling 6500 kg
3.XMW AWC Generator 3100~3750 kW 700~1380 rpm 690 V N/A 50 Hz ≥97% IP54/IP23 (Slip Ring Chamber) IC86W 12500 kg
5MW AWC Generator 5300 kW 1200 rpm 6300 V 406 A 50 Hz ≥97% IP54/IP23 (Slip Ring Chamber) Air-to-Water Cooling 17600 kg
——END——

CRRC 2MW Air-to-Water Cooled Double Fed Induction Generator

Rated Power 2150 kW Rated Speed 1755 rpm
Rated Frequency 50 Hz Shaft Center Height 500 mm
Number of Poles 4 Stator / Rotor Rated Voltage 690 V / 312 V
Stator / Rotor Rated Current 1540 A / 614 A Stator / Rotor Winding Connection Δ / Y
Rated Efficiency ≥ 97 % Power Factor 0.9 ind – 1 – 0.9 cap
Rotor Open-circuit Voltage 1835 V ± 20 V Cooling Method Air-to-Water Cooled
Insulation Class H Protection Grade IP54 / IP23
Motor Weight 6500 kg
——END——

Squirrel cage wind turbine generator

Product Model

Rated Power

Rated Speed

Rated Frequency

Center Height

Number of Poles

Stator Rated Voltage

Stator Rated Current

Stator Winding Connection

Rated Efficiency

Power Factor

Insulation Class

Cooling Method

Motor Weight

Protection Class

2.5MW Generator 2650 kW 1550 rpm 51.4 Hz 630 mm 4 750 V 2307 A Delta (△) ≥97% ≥0.88 H Air-to-Air Cooled 8350 kg IP54
——END——

Permanent magnet wind generator

Product Model

Rated Power

Rated Voltage

Number of Phases

Protection Class

Rotational Speed

Rated Current

Weight

7.6MW Semi-direct PMSG 7600 kW 690 V N/A N/A 278 rpm 3347 A 48.5 t
3.6MW Semi-direct PMSG 3830 kW 690 V 3 IP54 350 rpm N/A 17.5 t
3MW Integrated Semi-direct PMSG 3200 / 3400 / 3620 kW 710 V 3 IP54 480 / 526 / 550 rpm N/A 12 t
1.5MW Direct-drive PMSG 1580 kW 720 V 6 IP23 16.6 – 20.5 rpm 720 A 44 t
2.0MW Direct-drive PMSG 2120 kW 720 V 2×3 IP54 14 rpm 2×1006 A 49 t
2.5MW Direct-drive PMSG 2650 kW 690 V 2×3 IP54 13.5 – 16 rpm 2×1394 A 53 t
3.0MW Direct-drive PMSG 3350 kW 690 V 2×3 IP54 12.2 – 13.9 rpm 2×1800 A 69 t
——END——

General Infomation of CRRC Stator Coils for Wind Turbines Above 1.5MW

Product Model 7MW Stator slots 192
Rated voltage 1400 V Winding pitch 1-11
Turns per coil 6 Weight 4.05 kg
Scale 1:01
——END——

Technical Requirements

When the voltage phase sequence of the three-phase power supply is the same as the order of the terminal letters U, V, W on the motor terminals, the motor shall rotate counterclockwise when viewed from the shaft extension end; the bearing grease shall be BEM41-141, the lubrication cycle of the front and rear bearings is 0.5g or a similar amount of lubricating oil to be added every 8 hours, and the specific operation shall refer to the centralized lubricator operation manual.

Wind Power (Business Layout)

production-base

Wind Power (Market Situation)

As of December 2022, Yongji Electric has provided the wind power market with over 50,000 wind turbines (103GW), distributed across more than 1,800 wind farms both domestically and internationally. It comprehensively covers all wind power installation areas in China, accounting for 37% of the total number of wind turbines in operation, ranking first in the domestic market share.

 

Double

Note: All Above Data are Just for Reference, All Data Might Change Without Notices or Updates, Please Contact Our Sales Team to Confirm All Details Via WhatsApp or Email.

The picture of Sale Manual showing the accessories and scopes of supply.

Engine Sale Manual

The picture of Installation Drawing showing the accessories and scopes of supply.

Installation Drawing

The picture of Installation Manual showing the accessories and scopes of supply.

Installation Manual

The picture of Operation Manual showing the accessories and scopes of supply.

Operation Manual

The picture of Engine Parts Catalogue showing the accessories and scopes of supply.

Parts Catalogue

The picture of Test Report and Certifcate showing the accessories and scopes of supply.

Report & Certifcate

Global Activity

WhatsApp Online logo

Online Service


Sales Director-Mr.Jasper Lee

Sales Manager-Mrs.Wendy Fu

Spare Parts Sales-Miss. Nora Cao

After-Sales Manager-Ms. Tina Zhang

Merchandiser-Miss. Yoyo Tao

Contact EMAC Now!

Subscribe To Our Newsletter

Subscribe to get the latest updates from www.crrc-motor.com

Welcome on board, we will keep you updated with latest news and business activities!

Pin It on Pinterest